POWERFLUX safety power - POWERFLUX safety power rails are available or a current load from 0A up to 150A mobile electrification technology for moving transportation vehicles and equipment. Common application include : manufacturing robots, material handling systems, hoist and cranes, automated storage facilites and retrieval systems. POWERFLUX safety power rails are available in variety of configuration depending on applications requirements. Enclosed conductor system typically enclosed conductors in a protective conduit meeting safety standard.
|
|
Powerflux Main Unit 3P 120A, PX3120
Best Price : Rp 830,270 / Unit
Promo Price : Rp 597,794 / Unit
|
* Price exclude PPN, Ex-Works Cikupa
* Price & Spec can be changed without prior notification
SKU - DHC-969
POWERFLUX Conductor Rail for monorail travel 120A
Powerflux PVC Insulated Copper Conductor Rail
• Application include : manufacturing robots, material handling systems,
hoist and cranes, automated storage facilites and retrieval systems.
• Max Current : 120A
• Poles : 3
• Conductor Cross Section (mm2) : 3x10
• Conductor Rating : 600V 120A (1x120A)
• Conductor Bar : Cooper
• Insulation : PVC (Heat Resistance 75°C)
• Parts / Aksesoris : Plastic / Galvanied Steel
Parts :
Powerflux PVC Standard Hanger
Powerflux 3in1 Collector Arm + Collector Shoe 60A
Powerflux Towing Arm
Powerflux End Tensioner
Steel L Brackets + Bolts & Nut
Features
+ Conductor Material : OFC 99,99% Fine Copper
+ Insulator : Rigid PVC (Heat Resistance 75°C)
+ Orange (Safety Color), Munsell 2.5YR6/13.
+ Max. Radius Bending : 800mm.
+ Max. Conducting Speed : 300 m/min.
+ Max. Voltage : 600VAC
+ Dielectric Strength : 35-45 Kv/mm
+ Self Extinguishing : Class B1
+ Flexibility Strength : 78 Nm/mm2
+ Tensile Strength : 45 Nm/mm2
REQUEST QUOTE
Get your quotation less than 1 minute now!!
Cross Sectional Dimension & Properties
- Rating : 3P, 4P, 6P; 600V; 50A ~ 150A.
- Conductor Material : OFC 99.99% fine copper.
- Insulator : Rigid PVC (Heat Resistance 75°C) Orange (Hazard Color), Munsell 2.5YR6/13.
- Installation Method : Tension type.
- Available Length : Continuous up to 1000m
- Max. Radius Bending : 800mm.
- Max. Conducting Speed : 300 m/min.
- Suitable for vertical installations * Indoor use only.
ELECTRIFICATION PURPOSE
POWERFLUX safety power rails are available in variety of configuration depending on applications requirements. Enclosed conductor systems typically enclosed conductors in a protective conduit meeting safety standard. POWER CALCULATION (1) Determine the motor load current by calculation based on the nameplate, catalogue, indoor wiring regulations, and other pertinent regulations. For a general estimation, assume 4A per 1Kw at 200V (2) If the demand factor, power factor and other relevant values are known, use them to correct the calculation for the load current. Also, try to select the most cost-effective setup, taking such points as additional power installation into consideration. (3) for an overhead traveling crane, you may use the following equation for calculation :

EFFECT OF VOLTAGE DROPS
When the installed wiring is very long, voltage drops affect the motor and other loads positioned far from the power supply. If the voltage drop is too extreme (according to calculation of rop at the farthest point from the power supply when the total load current is applied), the rated current on the wiring should be raised by one step, or the power supply points should be changed or increased in number. The voltage drop in between the distribution board and the power supply points should also be taken into account. VOLTAGE DROP CALCULATION EQUATION (three phase, three wire) :
E = √3 * I * Z * L
Where “I” is total rated load current (A), “Z” is impedance (Ω/m), and “L” is line length (m).
** For example 50A rated current will be installed for 90m, the drop voltage will be 5V as shown on the chart.
** Generally for more than 100m installation, use middle power feed to minimize the drop voltage effect.

POWERFLUX CLIENT IN INDONESIA